IR400 Infrared Gas Analyzer




The IR400 infrared gas analyzer is capable of measuring the concentrations of NO, SO2, CO2, CO, CH4 and O2 components in sample gas. NO, SO2, CO, CO and CH4 are measured by the nondispersion infrared method (NDIR), while O2 is measured by the built-in type paramagnetic method sensor or an external mount-type zirconia method sensor. A maximum of 5 components including O2 (max. 4 components except for O2 measurement) are simultaneously measurable.

The mass flow type twin detector of high sensitivity and reliability adopted in the infrared ray method detection unit makes the measurement hardly affected by interfering components. In addition, the IR400 includes a microprocessor and has a large-size liquid crystal display, iproviding easy operation, high accuracy and multiple functions.


Features

* Simultaneous and continuous measurement of up to 5 components including O2 and 4 components selected from among NO, SO2, CO, CO2, and CH4.
* The mass flow type twin detector of high sensitivity and reliability minimizes interference from other gas components, ensuring excellent stability.
* Incorporating O2 correction, average value computing, automatic calibration, one touch calibration, upper/lower limit alarm, remote measurement range changeover, range identification signal output, etc., the analyzer accommodates different application requirements.
* Large LCD provides clear indications of all measured components and computed values and easy interactive operation.
* Unitized construction of the main body on the 19-inch rack and of the signal input/output terminal module allows easy configuration of a gas analyzer system.
* A maximum range ratio of 1:25 is achieved.

IR200 Universal Infrared Gas Analyzer



The IR200 infrared gas analyzer is capable of measuring the concentrations of CO2, CO, CH4, SO2, NO and O2 components in sample gas. CO2, CO, CH4, SO2 and NO are measured by the non-dispersion infrared method (NDIR), while O2 is measured by the paramagnetic or zirconia method. A maximum of 4 components including O2 (max. 3 components except for O2 measurement) are simultaneously measurable.

A high-sensitivity mass flow sensor is adopted in the detection block for the infrared method. Due to use of a single beam system for measurement, maintenance is easy and excellent stability is ensured for a long period of time. In addition, a microprocessor is built in and a large-size liquid crystal display is provided for easier operation, higher accuracy and more functions.

This analyzer is thus optimum for combustion control of various industrial furnaces, botanical study and global atmospheric research.


Features


* Simultaneous measurement of up to 4 components including O2 and 3 components selected from among CO2, CO, CH4, SO2, and NO.
* A unique optics system minimizes drift particularly due to contamination of measurement cell, ensuring excellent long-term stability.
* The dual cell type of transmission detector minimizes interference from other gas components.
* Single beam system allows for simple measurement unit construction and requires no adjustment of optical balance, resulting in low maintenance.
* Large LCD provides easy interactive operation.
* Highly precise zero/span calibration and automatic calibration are available. Self-diagnostic function detects abnormality and displays an error massage.

IR100 Universal Infrared Gas Analyzers



The IR100TA and IR100A, dedicated for analysis of either CO2, CO, or CH4, IR100TB and the IR100B, dedicated for simultaneous analysis of CO2 and CO, are available. The analyzers are easy to maintain and works steadily over long periods.

The ideal application of these analyzers are continuous measurement for the control and monitoring of combustion in various industrial furnaces as well as continuous measurement for the study of plants.

Features


* Two available models: simultaneous dual-gas (CO and CO2) measurement model and single-gas dual-range measurement model
* Stable operation over long periods
* Influenced less by presence of another interfering gas
* Easy maintenance
* Wide variety of additional functions: self-diagnosis, simple calibration, automatic calibration, remote switching measuring range, and range identification